[Mar 10, 2022] BraindumpsVCE H12-421 Exam Practice Test Questions (Updated 240 Questions) Pass Huawei H12-421 Exam Info and Free Practice Test NEW QUESTION 72 The scenario is complex, and the difficulty of creating a new site is the only challenge facing the development of traditional data center services. A. FALSE B. TRUE Answer: A NEW QUESTION 73 NetEco mobile app supports WiFi with a maximum effective [...]

[Mar 10, 2022] BraindumpsVCE H12-421 Exam Practice Test Questions (Updated 240 Questions) [Q72-Q95]

Share

[Mar 10, 2022] BraindumpsVCE H12-421 Exam Practice Test Questions (Updated 240 Questions)

Pass Huawei H12-421 Exam Info and Free Practice Test

NEW QUESTION 72
The scenario is complex, and the difficulty of creating a new site is the only challenge facing the development of traditional data center services.

  • A. FALSE
  • B. TRUE

Answer: A

 

NEW QUESTION 73
NetEco mobile app supports WiFi with a maximum effective distance of ( ) meters.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 74
The user can modify the ECC800's IP address from the () menu of the ECC800 Web interface.

  • A. Monitoring module IP
  • B. Emblem module settings
  • C. Video IP settings
  • D. Time setting

Answer: A

 

NEW QUESTION 75
DOD (depth of discharge) indicates the percentage of battery discharge and battery rated capacity.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 76
In NetEco "Video" function, you can enter ( ) and other operations (Multiple choice)

  • A. Delete the camera
  • B. Modify the camera
  • C. Create a camera
  • D. Video live browsing

Answer: A,B,C,D

 

NEW QUESTION 77
Users can monitor the status of devices such as UPS and air conditioner on the ECC800.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 78
When the air conditioning outdoor of Huawei air-cooled air conditioner is installed horizontally, it is required to be ≥ () mm from the wall or obstacle.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 79
In the "Video" function of NetEco, you can perform operations such as (). (Multiple Choice)

  • A. Delete the camera
  • B. Modify the camera
  • C. Create a camera
  • D. Video live browsing

Answer: A,B,C,D

 

NEW QUESTION 80
When the NetCol5000-A removes the air conditioning humidifier, the steps to maintain the electrode humidifier include (). (Multiple choice)

  • A. Remove the drain tank and drain valve component
  • B. Replace the hardened and brittle hose thoroughly flush the drain
  • C. Remove and clean the water supply valve
  • D. Disconnect the water supply valve and drain valve wiring

Answer: A,B,C,D

 

NEW QUESTION 81
After the air conditioner is commissioned, the indoor temperature is in a reasonable state, and the suction pressure is not lower than ( ).

  • A. 0.7MPa
  • B. 5MPa
  • C. 7MPa
  • D. 6Mpa

Answer: A

 

NEW QUESTION 82
In the water side natural cooling scheme, cooling water can be directly supplied from the cooling tower to the air conditioner to complete the cooling.

  • A. True
  • B. False

Answer: A

 

NEW QUESTION 83
The RH2288 server supports () power input.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 84
When the NetCol5000-C commissions the drainage device, lift the high floater by hand for 5 seconds. At this time, the dual water pump is turned on at the same time, and the "discharge abnormality alarm" appears.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 85
The UPS5000-E can press the battery cold start button on the bypass module without the main bypass input to start the inverter, and the system will automatically enter the battery inverter mode.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 86
When the UPS5000-E is equipped with an IP21 component, the ejector component can also be installed.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 87
Which of the following air conditioning systems need to be equipped with a cooling tower or dry cooler?

  • A. CW air-cooled type
  • B. DX water-cooled type
  • C. Direct ventilation air conditioning system
  • D. DX air-cooled type

Answer: B

 

NEW QUESTION 88
When the ECC800 detects that the connection signal to the device is interrupted, a communication interruption alarm is generated. What are the possible reasons? (Multiple choice)

  • A. Equipment failure
  • B. Cable connection is loose
  • C. Poor cable contact
  • D. Power supply is not normal

Answer: A,B,C,D

 

NEW QUESTION 89
Can a sunroof actuator drive up to several sunroof electromagnetic locks at the same time?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 90
() air supply method must have a reasonable raised floor height.

  • A. Upper hood air supply
  • B. Row level horizontal air supply
  • C. Upper air duct air supply
  • D. Under the floor air supply

Answer: D

 

NEW QUESTION 91
In general, the air supply distance of the air duct is shorter than that of the hood air supply.

  • A. FALSE
  • B. TRUE

Answer: A

 

NEW QUESTION 92
The refrigerant air cylinder of the Huawei air-cooled air conditioner does not need to be inverted on the electronic scale when charging the refrigerant.

  • A. FALSE
  • B. TRUE

Answer: A

 

NEW QUESTION 93
The PDU8000 intelligent power meter parameter display is abnormal, which may be caused by (). (Multiple choice)

  • A. Corresponding current transformer failure
  • B. Intelligent power meter failure
  • C. The corresponding voltage collection line is abnormal.
  • D. Electricity or voltage ratio setting error

Answer: A,B,C,D

 

NEW QUESTION 94
The ECC800 supports two AC inputs.

  • A. TRUE
  • B. FALSE

Answer: A

 

NEW QUESTION 95
......